§ 24-156. Restrictions.  


Latest version.
  • On or after October 1, 1991, no construction may be initiated within the city for any residential building of any type which:

    (1)

    Employs a gravity tank-type, flushometer-valve, or flushometer-tank toilet that uses more than an average of one and six-tenths (1.6) gallons of water per flush; provided, however, this paragraph shall not be applicable to one-piece toilets until October 1, 1991;

    (2)

    Employs a showerhead that allows a flow of more than an average of two and five-tenths (2.5) gallons of water per minute at sixty (60) pounds per square inch of pressure;

    (3)

    Employs a urinal that uses more than an average of one (1.0) gallon of water per flush;

    (4)

    Employs a lavatory faucet or lavatory replacement aerator that allows a flow of more than two (2.0) gallons of water per minute; or

    (5)

    Employs a kitchen faucet or kitchen replacement aerator that allows a flow of more than two and five-tenths (2.5) gallons of water per minute.