§ 7.5-35. As-builts.  


Latest version.
  • As-builts shall be required before the final plat is recorded for subdivisions or before a certificate of occupancy issued for commercial/industrial sites. All as-built drawings must be on standard twenty-four (24) inches × thirty-six (36) inches sheets with a maximum scale of one (1) inch = fifty (50) feet. Electronic files must also be submitted in AutoCAD format with water, sewer and storm system all on separate layers.

    (a)

    The water system as-builts shall show locations of fire hydrants, line valves, tees, water main sizes, and types of materials.

    (b)

    The sanitary sewer system as-builts shall show locations of manholes, lines, services, line sizes, types of materials, manhole inverts, and line grades.

    (c)

    Street ands storm sewer as-builts shall show street layout, profiles, grades, storm sewers and sizes, storm drainage structures, and detention ponds.

    (d)

    Commercial site layout as-builts in addition to water, sanitary sewer, and storm sewer, as-builts shall include, but not limited to, the following final locations of building(s), entrance(s), parking, and grading on computer disk in AutoCAD format (if feasible).

    (e)

    Sprinkler system as-builts with head count.

(Ord. No. 32-98, § 1, 8-27-98; Ord. No. 68-04, § 6, 9-2-04)